Advantages of Half-Cell Design

Release time:2024-07-15

Release time:2021-09-15

Author:

Author:


1. Lower Encapsulation Losses

Due to the reduced internal current and circuit resistance, internal circuit losses are decreased. Power loss is proportional to current; half the current and a quarter of the resistance allow half-cell modules to reduce power loss by four times, increasing output power and electricity generation. Additionally, lower internal losses reduce the module and junction box's operating temperature. In outdoor working conditions, half-cell modules have a temperature approximately 1.6°C lower than full-cell modules, resulting in higher photoelectric conversion efficiency.

Even if all half cells are connected like standard solar panels, the current is halved, but the resistance remains the same, reducing power consumption to a quarter.

 

2. Reduced Hot Spot Risk from Shading Tolerance

Half-cell panels better resist shading effects compared to standard solar modules. Unlike standard modules with three panel cell strings, half-cell modules have six cell strings, creating a six-string panel. Although shading on a small part of the module (such as leaves or bird droppings) can cause a cell string to fail, the bypass diodes (marked in red in the diagram) ensure the string does not affect other cell strings, reducing shading impact.

Six independent cell strings with three bypass diodes provide better local shading tolerance. Even if half the module is shaded, the other half can still operate.

 

3. Lower Current Reduces Hot Spot Temperature

Half cells distribute internal current in the system, improving performance, lifespan, and shading tolerance. When a cell string in the module is shaded, it creates a hot spot in the circuit. Sustained high temperatures can damage the module. With twice the number of cell strings, the heat at the hot spot is halved, reducing damage and increasing the module's resistance to hot spot damage and its lifespan.

 

 

4. Reduced Power Loss from Shading Tolerance

In a PV array, multiple modules are generally connected in series, then paralleled with other sub-strings. Current flows sequentially through each series-connected module in the same sub-string.

 

For traditional module designs, if one module loses power due to shading, it affects all modules in that sub-string. In half-cell modules, bypass diodes limit power loss to the shaded part rather than the entire module. They create an alternative path for current flow in the non-shaded portion, avoiding current through the shaded part, reducing shading impact, and enhancing performance.